H1 / Before installation

Have a qualified professional install this equipment. Use high-quality diesel, not kerosene, vegetable oil, gasoline, waste oil, or other fuels: these may cause odors or malfunction.

From the H1 owner's manual

H1 / Location and protection

  • Protect nearby components from heat with specified minimum clearances, ventilation, and fire-resistant materials or heat shields. Protect the heater from mechanical impact and other damage. If within the driver's reach during normal operation, install a guard. If outside, protect from splashing water. Prevent water entering when passing through water up to the permitted fording depth.

From the H1 owner's manual

H1 / Hot-air route

  • WARNING: Keep sufficient clearance between hot-air outlet and occupants; prevent contact with hot surfaces and direct exposure to the hot-air stream. Draw cold intake air from a clean area so combustion exhaust cannot enter it. NOTE: Keep inlet-to-outlet duct pressure loss below 2 hPa or heating output will fall. Do not integrate with the vehicle air system or connect to an externally controlled distribution system such as the vehicle air conditioner. Temperature control: The heater adjusts output to heating demand, according to the room-temperature sensor and control-panel target.

From the H1 owner's manual

H1 / Duct materials

  • Use ducts rated for continuous temperatures of at least 130°C (150°C for short periods); recommended inside diameter is 75 mm. Orient cold- and hot-air ducts correctly, secure all connections, and minimize airflow resistance.

From the H1 owner's manual

H1 / Combustion air

  • Do not draw combustion air from an enclosed area occupied by people. The inlet must not face the direction of travel and must be protected from debris. Draw air from a cool location protected from splashing water, above the specified wading depth. Use only the supplied intake pipe. An intake silencer is recommended if the pipe is shorter than 0.6 m.

From the H1 owner's manual

H1 / Exhaust materials

  • Use exhaust pipe made of non-alloy or alloy rigid tubing at least 1.0 mm thick, or flexible tubing made only of alloy steel. Secure it with the supplied clamp; recommended inside diameter is 24 mm. Use corrosion-resistant material. Do not attach a muffler to heat-sensitive components; maintain clearance and use heat shields if needed. Ensure the muffler condensate drain hole does not point toward heat-sensitive components.

From the H1 owner's manual

H1 / Pipe lengths

  • Total intake and exhaust pipe length: maximum 2.0 m with muffler, 5.0 m without muffler. Insulate exhaust pipe longer than 2 m to prevent temperature falling below the dew point. Recommended inside diameters: intake 25 mm, exhaust 24 mm; minimum bend radius 50 mm; maximum total bend angle 270° for each pipe.

From the H1 owner's manual