Before initial startup, fuel must reach the fuel inlet. Use Option A (recommended); if it does not succeed, use Option B.
A1 / First start-up
Option A (recommended): automatic fuel priming
A1 / First start-up
When starting for the first time, press “Settings” five times in succession. The system starts a 200-second fuel-priming mode and displays a countdown. During priming, it continuously monitors the fuel signal. When the glow plug detects fuel, the unit automatically ignites and starts. Press any button to stop early.
A1 / First start-up
Option B: manual fuel pumping
A1 / First start-up
The heater has a long fuel line. Before initial startup, manually pump fuel to the fuel inlet. Otherwise, after starting the unit, allow time for it to detect fuel; the system continuously monitors the fuel signal. Once the glow plug detects fuel, ignition and heating begin automatically.
A1 / First start-up
Avoid over-priming
A1 / First start-up
Pump fuel only until it reaches the fuel inlet, then stop. Excess fuel inside the unit prevents normal ignition and produces white smoke. If too much fuel has been pumped, disconnect the fuel line and restart the unit 2–3 times until normal operation is restored, then reconnect the fuel line. Alternatively, continuously blow air through the fuel inlet line with a hair dryer until the unit resumes normal operation.
A1 / First start-up
Switch on
A1 / First start-up
With the unit off, press and hold “On/Off” for 2 seconds. “Preheating” indicates that the unit has entered heating mode. At initial startup the default is Manual Mode, with level “5L” in Standard Mode.
A1 / Operating the heater
- Start: With the unit off, hold “On/Off” for 2 seconds. The initial default is Manual Mode, “5L” in Standard Mode.
A1 / Operating the heater
- Shut down: While operating, hold “On/Off” for 2 seconds. The display shows “OFF,” then “Shutdown Cooling” until cooling completes and the unit shuts down. Do not operate the button during shutdown. NOTICE: Never disconnect power during shutdown. Otherwise internal heat cannot dissipate completely; restarting may produce a large amount of smoke, and insufficient cooling can damage the internal combustion air fan impeller. Allow combustion to finish completely before resuming normal operation. Disconnect power only after heat dissipation is complete and the fan has stopped; the unit is fully shut down when the control panel turns off.